Breakdown

Have a detailed look of the machine and it's most powerful features

brake-down

Automation system

max.e 3- DH is fully equipped with all necessary automation and all executive mechanisms. The electric switchboard is integrated into the unit and located on the operation side. The "Brain" of max.e3 is specially designed by Damvent controller, which controls and manages all processes and protects the unit from eventual cut-offs.

Rotary heat exchanger

All of the max.e 3-DH units use an air-to-air rotary heat exchanger- Sorption type, made from aluminium foil and a 3Å molecular sieve which gives high sensitivity for absorbing water molecules (HM1 type). Sorption rotors provide an excellent method to pre-cool and dehumidify the fresh air before entering the DX cooling coil. Temperature efficiency (Sensible) - E ≥ 70%, Humidity - E ≤ 80%

Heat pump

100% DX unit. No additional water, electric or DX heating/cooling coils are needed in the max.e 3-DH, which makes it independent of other additional heating/cooling sources (boilers, chillers, VRF systems, etc.)

Additional DH Re-heater

The additional re-heater is an integral part of the refrigerant circuit and recovers heat. The re-heated air is supplied with the desired parameters (e.g. T/RHsupply = 18°C/50%) without using any electric or water source.

Fans

max.e 3-DH use ZAbluefin plug fans with the latest EC Blue (Electronically Commutated) from Ziehl-Abegg. The fan wheel is statically and dynamically balanced on the axis of the direct-driven motor. The fan wheel and the motor are mounted on a common base frame with vibration dampers.

Integrated steam humidifier

During the winter season, we recover up to 85% of the extract RH(%) from the room, but still, an additional steam humidifier must be implemented into the max.e3-DH to reach the necessary Rhroom(%) or to produce the required humidity when the unit is being started up. The humidifier could be fully integrated within the unit or installed within the building, but in both cases controlled by our ICB.

Concepts

Learn more about what the main advantages of hybrid HVAC solutions for fresh air treatment
  • 3E - Concept
  • 3 STAGE HEAT/COOL/HUMIDITY RECOVERY TECHNOLOGY
  • All in 1
  • 100 % Factory tested
  • 100% Plug and play

1е - Every Climate – from -30°C to +55°C

2е - Every Application –suitable for every application where 100% fresh air is needed, by means of covering all possible air treatment processes:
Recirculation 0÷100%
Heating
Cooling + Dehumidifcation
Process Ventilation.

3е - Every Installation - Every Installation - suitable for all types of installation, indoor (plant rooms, technical floors, etc.) and outdoor.

achieved - "consecutively" in 3 stages:
1st stage - Cool / Humidity Recovery in the rotary wheel +

2nd stage - deep cooling and dehumidifcation in the evaporator +

3rd stage - re-heating by the additional re-heater (condenser) in summer, spring and autumn seasons and 1.Heat/Humidity recovery by the rotary wheel + 2.Heating by the Condenser + 3.Humidification by the Steam Humidifier in the winter season.

max.e - multifunctional concept solution for fresh air with built-in reversible heat pump and integrated automation system.

High reliability and reduced installation costs, achieved by 100% factory tests - each unit is tested under factory conditions
The factory test includes:
· Leakage check
· Vacuuming and loading the system with the exact refrigerant quantity
· Functional testing of all fans and compressors
· Loading the controller's software
· Temperature and pressure checks
· Setting up the required air flow
· Recording all parameters of the unit on a test list

Stand alone "one-piece" unit, which only needs a duct system and power supply for start up.

Performance

Take a look at the improved technology

  • It is a unique 3 stage Heat/Cool/Humidity Recovery Hybrid designed to closely control the RH(%) and T(°C)
  • MAX.E3 DH* is designed to maintain T/RHsupply (°C/%) around the world, throughout the whole year
Read More

COP/SCOP/SPF

Higher than the highest standards!
A conventional air-cooled heat pump uses the ambient air for the evaporation process, and during the winter, this air can reach temperatures of -10°C, -15°C or even -20°C. Extracting heat from the ambient air is an inefficient process. In comparison, max.e3 uses the extract air from within the room.
Learn more
 COP/SCOP/SPF

Hardware

Everything you need to know about the machine’s components

  • Design

    The solutions from the max.e3 - DH series are designed and manufactured in accordance with EN 1886 – (Ventilation for buildings-Air handling units Mechanical Performance).
    max.e3-DH is designed as a system with the structure of the unit, manufactured as a mono-block (from size max.e3-02 DH to size max.e3-18 DH. Bigger sizes like max.e3-25, 30, 35 DH are produced on sections) consisting of aluminium profile, supporting elements, connection angles and locking accessories.

    Learn more
    Design
  • Rotary heat exchanger

    Rotary heat exchanger

    All of the max.e3-DH units of the type max.e3-DH use an air-to-air rotary heat exchanger- Sorption type, made from aluminium foil and 3Å molecular sieve, which gives high sensitivity for absorbing water molecules (HM1 type). Sorption rotor provides an excellent method to pre-cool and dehumidify the fresh air before entering the DX cooling coil. Temperature efficiency (Sensible) – E ≥ 70%, Humidity Efficiency – E ≤ 80%.

    Learn more
  • Heat pump

    100% DX unit
    No additional water, electric or DX heating/cooling coils are needed in the max.e3-DH, which makes it independent of other additional heating/cooling sources (boilers, chillers, VRF systems, etc.)

    Learn more
     Heat pump
  • Fans

    Fans

    max.e3 - DH uses ZAbluefin plug fans with the latest EC Blue (Electronically Commutated) from Ziehl-Abegg. The fan wheel is statically and dynamically balanced on the axis of the direct-driven motor. The fan wheel, together with the motor, is mounted on a common base frame with vibration dampers.

    Learn more
  • Automation System

    max.e3 - DH is fully equipped with all necessary automation and all executive mechanisms. The electric switchboard is integrated into the unit and located on the operation side. 
    The "Brain" of max.e3 - DH is its specially designed by Damvent controller, which controls and manages all processes and protects the unit from eventual cut-offs.

    Learn more
    Automation System
  •  Connectivity and mobility

    Connectivity and mobility

    All hybrid units allow into the corresponding connector of the ICB controller to be mounted specialized internet circuit board for internet connection. The built-in circuit board allows a permanent internet connection to max.e3-DH  from any location in the world. This option helps you/us to make adequate reactions to situations requiring fast and accurate solutions to the problem.

    Learn more
  • Filters

    Filters are installed at the entrance of the unit to ensure the normal operation of the AHU and to prevent contamination of the components. 
    Microcell filters are used in the units max.e3-DH. These filters are made of plated micro-glass paper and spaced with hot melt adhesive beads, which are uniformly positioned to deliver optimum airflow.

    Learn more
    Filters
  • Integrated Steam Humidifier

    Integrated Steam Humidifier

    During the winter season, we recover up to 85% of the extract RH(%) from the room, but still, an additional steam humidifier must be implemented into the max.e3-DH to reach the necessary Rhroom(%) or to produce the required humidity when the unit is being started up. The humidifier could be fully integrated within the unit or installed within the building but in both cases controlled by our ICB.

    Learn more

Advantages

  • For the Investor
  • For Designers and Consultants
  • For installation companies

· Significant reduction in initial investment costs
· Significant reduction of installed power
· Low operating (energy) costs
· Saved Space
· Easy maintenance – mono-block unit
· Internet monitoring
· 100% Factory Tested
· Low noise performance

· Significant reduction in initial investment costs
· Significant reduction of installed power
· Low operating (energy) costs
· Saved Space
· Easy maintenance – mono-block unit
· Internet monitoring
· 100% Factory Tested
· Low noise performance
· Specialized Selection Software available and free to use
· Saves design time
· Flexibility of installation on site for the unit
· Fast and easy calculation of energy consumption on an annual basis

· Easy installation on site (needs only connection to the ducts system and power supply)
· Connection to the BMS system through different protocols
· Setting up the unit through the internet
· Lack of working with refrigerants on site

Capital Cost Comparison

Hybrid AHU with built-in heat pump and integrated automation system

Traditional systems
  • Classic AHU with DH/Water coil section and additional Electric or Water Re-heater
  • External condensing unit/VRF or Water chiller (low temperature)
  • Steam Humidifier, installed inside the AHU or within the duct system
  • Hot water boiler for low ambient temperatures
  • Pipe system with all necessary and attached accessories- insulation, fittings, etc.
  • Pumps (for water systems), or AHU kit for VRF
  • Installation labor for two or more systems
  • Common automation system
  • Significantly Higher installed electric power and Higher Energy Consumption
  • Higher costs for BMS - for controlling two or more systems
  • Significantly bigger footprint for installation
  • Higher Sound Noise Level

Contact Us

Our other products

You can download the Autocad files of the machines here.

max.e2
max.e2

max.e2 - Hybrid AHU with "2 stage thermodynamic heat recovery technology"- recovering up to 100% of the extract heat from the room.

Learn more
max.e3
max.e3

max.e3 - Hybrid AHU with "2-stage thermodynamic heat recovery technology"- recovering up to 100% of the extract heat/cool/humidity.

Learn more
max.e-mini
max.e-mini

max.e-mini - Hybrid AHU with “2-stage thermodynamic heat recovery technology”- recovering up to 100% of the extracted heat from the room.